Product Details
Product Description:
GuangHong PLC Splitter is an integrated waveguide optical power distribution device based on a quartz substrate. Like the coaxial cable transmission, the optical network system also needs to couple, branch, and distribute optical signals. Need optical splitters to achieve. At the same time with multiple inputs and multiple outputs. Micro-box structure of the micro PLC optical splitter, with stronger fiber protection.
PLC Splitter 1x4 Feature:
Excellent environmental stability
Low Insertion loss and Low PDL
Uniform power splitting
Convenient engineering applications
Fine polarization
Wide scope wavelength
Tight and fine structure
Excellent parameters on IL & RL
High reliability and directivity
Non-sensitive wavelength
Compact size and various package
PLC Splitter 1x4 Application:
CATV network
LAN, WAN and Metro Networks
Testing equipment
Fiber optic communication system
FTTX access network based on PON structure
Local loop and passive optical network (PON)
Product Specification:
Table 1 – 1×N PLC Fiber Splitter
1×N (N≥2) PLC splitter Parameters |
Item |
unit |
Parameters |
Operating Wavelength |
nm |
1260-1650 |
Structure |
/ |
1×2 |
1×4 |
1×8 |
1×16 |
1×32 |
|
Max Insertion Loss (dB) |
dB |
4.1 |
7.4 |
10.5 |
13.8 |
17.1 |
20.4 |
Max Uniformity |
dB |
0.8 |
0.7 |
0.8 |
1 |
1.5 |
2 |
Max Polarization Dependent Loss (PDL) |
dB |
0.2 |
0.2 |
0.2 |
0.3 |
0.3 |
0.3 |
Return Loss |
dB |
50 (UPC); 55 (APC) |
Min Directivity |
dB |
55 |
Working Temperature |
°C |
-40 ~ +85 |
Storage Temperature |
°C |
-40 ~ +85 |
*Insertion lost for splitters with connectors will be 0.3 dB less. |
Table 2 – 2×N PLC Fiber Splitter
2×N(N>2)PLC splitter Parameters |
Item |
unit |
Parameters |
Operating Wavelength |
nm |
1260-1650 |
Structure |
/ |
2×4 |
2×8 |
2×16 |
2×32 |
2×64 |
Max Insertion Loss |
dB |
7.7 |
10.8 |
14.1 |
17.4 |
20.6 |
Max Uniformity |
dB |
0.7 |
0.8 |
1 |
1.5 |
2 |
Max Polarization Dependent Loss (PDL) |
dB |
0.2 |
0.2 |
0.3 |
0.3 |
0.3 |
Return Loss |
dB |
50 (UPC); 55 (APC) |
Min Directivity |
dB |
55 |
Working Temperature |
°C |
-40 ~ +85 |
Storage Temperature |
°C |
-40 ~ +85 |
*Insertion lost for splitters with connectors will be 0.3 dB less. |
Quality Control & Quality Assurance:
In GuangHong, every single splitter is tested multiple times at different production stages prior to shipment, with the strictest quality control procedures that use calibrated test equipment specific to your requirements.
Factory Assembly Line
Coupling the optical fiber to
the v-groove base plate
|
Coupling single fiber FA with
multi-fiber FA
|
Coupling the connectors and
quality control
|
Our Device
Quadratic element measure |
High and low temperature test box |
Grinding & Polishing machine |
Factory Overview:
http://www.ghcomms.com/